Mobile broadband router

MR-270

Remote access removes boundaries, eliminates the need for time consuming site visits and provide a network infrastructure suitable for today’s “always-on” society. The MR-270 mobile broadband GPRS / EDGE / 3G router uses the Internet to cost effectively inter-connect systems, allowing HMI, PLCs, sensors etc to communicate with each other.

Read more

The dual SIMs ensures high availability for critical applications. Bundle the mobile broadband GPRS with ADSL devices, Falcon or DR-260, for both wired and wireless access.

Devices connected to the Internet require countermeasures towards cyber threats. The MR-270 offers protection of transmissions from malicious eavesdroppers via encrypted communication tunnels (VPN, included), access prevention from unauthorized addresses, and extensive logging to detect intrusion attempts. With an advanced and highly configurable firewall the unit is easily set up to only allow valid application data.

The MR-270 with its built-in serial port offers a simple modem replacement solution with the benefit of not having to reprogram or change any other component. The powerful software in the MR-270 offers methods to engineers to easily analyze the data-flow, valuable for fast troubleshooting of connected devices.

The MR-270 supports GSM, GPRS, EDGE, 3G, HSPA, and is equipped with one serial port and four Ethernet ports.

Downloads

Technical data

MR-270

Product description
StatusActive
Article number3622-0205
Ports4 x 10 Mbit/s or 100 Mbit/s, Ethernet TX, RJ-45.
1 x 300 bit/s to 115.2 kbit/s, D-sub, RS-232.
2 x SIM slots.
1 x USB.
DescriptionMobile broadband router
Warranty period5 Years
Standard compliance
R&TTEArticle 3.1a:
EN 60950, Safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2:
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
Reliability prediction
MTBF, operating139 000 hours, Bellcore RQGR at 40°C
EMC (Electromagnetic Compatibility)
EN 55024Electromagnetic compatibility - Immunity IT equipment
EN 55024 + A1 + A2Electromagnetic compatibility - Immunity IT equipment
EN 55022Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement.
EN 55022 +A1Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement.
FCC part 15Class B
EMC specifications
EN 61000-4-2, ESDEnclosure contact, ± 4 kV
Enclosure air, ± 8 kV
IEC 61000-4-3, RF field AM modulatedEnclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transientsSignal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surgeTelecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunityPower ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruptionAC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emissionEnclosure, class B
FCC part 15, radiated RF emissionEnclosure, class B
EN 55022, conducted emissionAC power ports, class A
DC power ports, class B
FCC part 15, conducted emissionAC power ports, class B
Safety
SafetyUL/IEC/EN 60950-1, IT equipment
Climatic
Temperature, operating0 to +55ºC (32 to +131ºF)
Temperature, storage–40 to +85ºC (–40 to +185ºF)
Humidity, operating5 to 95% relative humidity
Humidity, storage5 to 95% relative humidity
Enclosure
EnclosurePressed steel
Dimensions (W x H x D)210 x 41 x 145 mm (8.3 x 1.6 x 5.9 in)
Weight0.9 kg
Degree of protectionIP 30
CoolingConvection
MountingHorizontal on 35 mm DIN-rail or flat on level surface
Interface specifications, power
Rated voltage11 – 58 VDC
Operating voltage11 – 58 VDC
Rated current1500 mA @ 12 VDC
Rated frequencyDC
Interface specifications, RS-232
Electrical specificationEIA RS-232
Data rate300 bit/s – 115.2 kbit/s
Data format7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
ProtocolTransparent, optimised by packing algorithm
Circuit typeSELV
Transmission range15 m / 49 ft
Connection9 pin D-sub female
Shielded cableNot required
Conductive housingYes
Number of ports1
Interface specifications, 10/100BaseTX
Electrical specificationIEEE std 802.3. 2005 Edition
Data rate10 Mbit/s, 100 Mbit/s, manual or auto
DuplexFull or half, manual or auto
Circuit typeSELV
Transmission range100 m / 328 ft
Isolation toAll other
ConnectionRJ-45 auto MDI/MDIX
Shielded cableNot required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Conductive housingYes
Number of ports4
Interface specifications, Antenna
Frequency bands850 MHz – 2100 MHz
ConnectionSMA female, impedance: 50 ohm
Interface specification, SIM
Electrical specification3 volts SIM supported
Number of slots2
Interface specifications, USB
Electrical specificationUSB 2.0 host interface
Data rateUp to 12 Mbit/s (full-speed mode)
Circuit typeSELV
Maximum supply current500 mA in total for both ports
ConnectionUSB receptacle connector type A
Number of ports1

Request a quote

Your contact information:
Your name:
Your company:
Your country:
Your telephone:
Your E-mail address:
Your message:
I would like to subscribe to your monthly newsletter
The subscription can be terminated at any time and your email address will not be forwarded or used for any other purpose.
You do not have JavaScript:

Mobile broadband router

MR-270